openPR Logo
Press release

CAS Dataloggers Offers New Compressor Monitoring Kit

02-21-2017 05:53 PM CET | Industry, Real Estate & Construction

Press release from: CAS DataLoggers

New Compressor Monitoring Kit

New Compressor Monitoring Kit

Help Prevent Process Delays with a Single Solution
Need a way to help avoid costly process delays and shutdowns? CAS DataLoggers has the solution! Our new Compressor Monitoring kit is a single solution which logs temperature, runtime, current consumption and voltage. The new kit also contains probes for measurement, a datalogger to take and store the readings, and built-in software to analyze the data.

Our kit is a cost-effective way to monitor single-phase compressor motors for both current and voltage, helping users to maintain them and to get an indication of when they are in danger of failing. By helping to prevent a process shutdown, the kit can pay for itself in a single event!

All-in-One Kit:

• Log Temperature, Current/Voltage, and On/Off state
• Large Internal Memory + USB port
• Choice of Communications—USB, RS-232, Modbus
• Intelligent Design Featuring Automatic Alarms & Commands

Typical Applications:

• Energy surveys take much less time when all the data is taken and extracted from a single system. This way users can quickly find out if a compressor is the correct size.

• Installers can use this portable but powerful kit to measure compressor On and Off time and the current consumption of a wide range of compressor models. Our system is easy for field personnel to operate with equally simple software.

• Condition Monitoring of recent current and voltage fluctuations helps ID failing single-phase compressor motors. For example, the motors’ effectiveness could be strained by low-voltage conditions. The included multichannel logger allows users to view the load on the compressors and see which are in danger of failing.

Your Choice of Sensors:

• Temperature: Thermocouples, RTDs, Thermistors, Ambient Temperature sensors

• Current/Voltage: Transducers, 4-20mA sensors, current clamps

• Optional: Panel-mount Maple Display, Enclosure

It’s easy to connect the DT80 to external voltage and current transducers and then hook them up to a single-phase compressor motors, a pair of motors at a time. The datalogger’s channels will then monitor their current/voltage levels according to your preferred logging schedule. The DT80 can also auto-alert workers to sudden current and voltage fluctuations in the motors.

Universal Data Loggers Offer Flexibility

The kit includes a dataTaker DT80 Intelligent Data Logger to monitor both compressor runtime and current consumption. To do this, users place a current clamp around the compressor supply, then check the logger’s display while the compressor is operating in its loaded and idle states. The dataTaker will then auto-record the current levels and On time to Off time. The DT80 can also log ambient temperature, which is useful in viewing compressor effectiveness.

The DT80’s universal inputs enable connection to most sensors so that current/voltage, temperature, 4-20mA loops, and more can be logged and scaled. Additionally the dataTaker’s durability provides years of reliable operation, and the logger’s large memory stores up to 10 million data points.

Your Choice of Communications

The kit’s datalogger features several communications options including RS232 with modem support, Ethernet, and USB memory stick ports. FTP can provide data directly to your office over the internet or mobile phone network. Built-in support for Modbus RTU communications gives the DT80 even more flexibility when monitoring compressors.

Analysis Software Included

Built-in dataTaker dEX software is included with the dataTaker datalogger for professional analysis. This software uses a Windows Explorer-style graphical interface allowing quick setup and configuration of the dataTaker. Users configure and run the software directly from a web browser to access the DT80 locally or remotely online. It’s easy to view all measurements in real time and display them as mimics. Operators can use any of the dataTaker’s integral communications ports to view dEX, including USB, Ethernet and RS-232.

For more info on the new Compressor Monitoring kit featuring the dataTaker DT80, or to find the ideal solution for your application-specific needs, contact a CAS DataLoggers Application Specialist at (800) 956-4437 or visit our website at www.DataLoggerInc.com.

Computer Aided Solutions, LLC. dba CAS Data Loggers is a distributor of data loggers, paperless recorders and data acquisition equipment.

Computer Aided Solutions
8437 Mayfield Road
Chesterland, OH 44026
(440) 729-2570
www.dataloggerinc.com

This release was published on openPR.

Permanent link to this press release:

Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.

You can edit or delete your press release CAS Dataloggers Offers New Compressor Monitoring Kit here

News-ID: 444585 • Views: 535

More Releases from CAS DataLoggers

Introducing OdaLog Gas Data Loggers from ThermoFisher
CAS DataLoggers is introducing OdaLog Odor & Gas Data Loggers, a family of portable gas monitors from ThermoFisher Scientific. Effective immediately, CAS will be responsible for the sales and support of all OdaLog products within the United States. OdaLog, owned by ThermoFisher Scientific Australia Pty Ltd, are used extensively in the wastewater industry to record the level of Hydrogen Sulphide (H2S) and other gas emissions in pumping stations, manholes and sewer
Visit CAS DataLoggers at Pittcon 2020
The World's Largest Lab Expo, March 3rd-5th in Chicago CAS DataLoggers is proud to announce that we will be exhibiting along with TandD US, LLC at Pittcon 2020! Pittcon is the world's leading annual conference and exposition on laboratory science. Hosted in Chicago, IL at McCormick Place on March 3rd-5th, Pittcon 2020 will draw a large crowd of attendees from industry, academia, and government from over 90 countries! This year, CAS
Visit CAS DataLoggers at AHR 2020
The World’s Largest HVAC event is about to get underway—the annual AHR 2020 Expo is returning to Orlando, FL on Feb 3-5th. CAS DataLoggers Sales Mgr. Peter Martin is proud to attend along with Japan’s #1 datalogger manufacturer—T&D! Come visit us at Booth #7490 to see our cutting-edge HVAC solutions for performance validation, energy audits, and more! With prices starting at just $109, T&D products give businesses and organizations an affordable
New ADwin-X-A20 Compact Data Acquisition System
CAS is pleased to announce the new ADwin-X-A20 compact data acquisition and control system. It features a high performance, dual-core, 64-bit processor plus analog and digital inputs and outputs and a 1GB Ethernet communications interface to provide extremely precise, low latency real-time operation. Programs can be quickly created using either the user-friendly ADbasic development environment or through Simulink via the ADsim interface. Standard Features: -XILINK ZYNQ ARM Cortex-A9 666 MHz CPU, 64-Bit

All 5 Releases


More Releases for DT80

Diesel Engine Monitoring System for Dredge Barge Engines Emissions & Maintenance
dataTaker Solution Helps Keep NY Waterway Open for Business A considerable amount of the seagoing freight enters the US through New York Harbor, one of the world’s largest and busiest. Keeping the harbor navigable is a full-time job that requires constant dredging to allow large oceangoing vessels safe access to the freight terminal. Each of these dredging barges utilizes multiple diesel engines to run its generators to power all the onboard
Controlled Atmosphere Storage Using a DataTaker
DT80 Provides Single Solution & Saves Money A company contacted CAS DataLoggers with a controlled atmosphere storage environment project as part of pilot testing for a new process. To reduce costs, existing equipment was used wherever possible. The hostile atmosphere produced was found to be incompatible with available humidity sensor technologies, requiring these measurements to be derived in real time using measurements from secondary sensors. The price of logging different sensors
Condition Monitoring of a Mining Quarry for Optimal Production
Versatile dataTaker DT80 CAS DataLoggers supplied the data logging solution for a major international building supplies provider experiencing regular downtime in one of their mining quarries. Raw materials were constantly moved using conveyor belts throughout the quarry, and evidence of a problem had surfaced when significant discrepancies between the manually-reported stoppages and the material throughput began appearing. To clarify this issue and to identify the cause of these discrepancies, an automated
Sophisticated Fuel Consumption Monitoring in a Gold Mine
dataTaker DT80 Helps Prove Product Outperformed the Competition CAS DataLoggers provided the data logging solution of fuel consumption monitoring for a company called FPC International, specializing in a diesel fuel additive widely used in tankers, trucks, and trains all over the world to save on fuel and engine maintenance costs while reducing carbon footprints and emissions. Rather than just making claims of their product’s benefits, FPC Intl. actively tested and documented
Utility Monitoring in a School Building
Universal Input Data Loggers Offer Total Building Solution A customer needed a utility monitoring solution to accurately monitor utility usage in a school building, totalized by floor. They needed to present this data in an easy-to-understand dashboard for each wing and as an aggregate total for the entire building. The client also had electric sub-panels on each floor, but they are separated from their floors’ main utility rooms; these needed to
Securing the dataTaker DT80 Series Web Services
Series 3 dataTaker Universal DataLoggers Series 3 dataTaker dataloggers are popular for their communications functionality and for their ease of programming using the built-in dEX software. In our latest Technical Article, CAS DataLoggers shows you how to assign password protection to your dataTaker DT80 series logger and how to limit access to its interface if desired. 1. Setting Changes (in dEX Software) NOTE: The changes specified in this document require your logger to