openPR Logo
Press release

Commonly Used Colorimetric Reagents in SPPS

09-30-2025 06:20 PM CET | Industry, Real Estate & Construction

Press release from: ABNewswire

In the field of solid-phase peptide synthesis, the completeness of each chemical reaction is crucial for determining the purity and sequence accuracy of the final product. The synthesis process follows a cyclic procedure of "deprotection-washing-coupling-washing" for stepwise chain elongation. Even a minor deficiency in the coupling efficiency of a single amino acid can lead to the accumulation of impurities such as deleted peptides, making subsequent separation and purification extremely challenging. Therefore, it is essential to monitor key steps including deprotection and coupling to confirm reaction completion. Owing to their operational simplicity, rapid response, and cost-effectiveness, colorimetric methods have become indispensable detection tools. These methods provide specific color changes that visually indicate the presence or absence of free amino groups on the resin, offering critical quality control checkpoints during synthesis. This article systematically elaborates on the chemical principles, reagent preparation, and practical considerations of several classic colorimetric reagents, providing technical guidance for peptide synthesis experiments.

1. NinhydrinTest (Kaiser Test)

The Ninhydrin Test, proposed by Ralph Kaiser et al. and also known as the Kaiser Test, is the most widely used technique for detecting primary amines (-NH) and is employed to monitor the presence of free amino groups during peptide synthesis. Its core mechanism involves treating a small sample of peptide-resin with the test reagents. Ninhydrin reacts with -amino groups (e.g., the N-terminal amine of the peptide chain) to form a characteristic blue-purple product-Ruhemann's Purple-with color intensity proportional to the amount of free amino groups present.

Note: The Kaiser Test does not detect secondary amines (e.g., proline) or amino groups lacking an -hydrogen (e.g., diaminoisobutyric acid, -methyl leucine, and other ,-disubstituted amino acids).

Image: https://ecdn6.globalso.com/upload/p/1839/image_other/2025-09/picture-111.png

1.1 Reagent Preparation

Three stock solutions must be prepared and mixed immediately before use. Recipes are as follows:

* Solution A:Weigh 5.0 g of ninhydrin and dilute to 100 mL with absolute ethanol. Store protected from light at room temperature. Valid for 1 month.
* Solution B:Weigh 80.0 g of phenol, add 20 mL of absolute ethanol, and dissolve completely (gentle heating may be applied to accelerate dissolution). Store protected from light at room temperature. Valid for 2 weeks. (Phenol oxidizes readily; prepare fresh before use.)

Safety Note: Phenol is highly corrosive and can be absorbed through the skin. Operate in a fume hood wearing nitrile gloves and safety goggles.

* Solution C: Add 2 mL of 0.001 M aqueous potassium cyanide (KCN) solution to 98 mL of redistilled pyridine.

Critical Hazard Alert: Potassium cyanide is extremely toxic-lethal dose is only 50-100 mg. It can be absorbed through skin, inhalation, or ingestion. Contact with acid releases lethal hydrogen cyanide gas. Prepare in a dedicated fume hood wearing a respirator, chemical-resistant suit, and nitrile gloves. Collect waste separately as highly toxic material and never allow contact with acids.

Note: KCN acts as a catalyst in the color reaction. If KCN is unavailable, it may be omitted. Additionally, during pyridine redistribution, adding a small amount of ninhydrin can help remove impurities that cause discoloration.

1.2 Testing Procedure

Transfer a small amount of washed resin into a test tube using a capillary tube. Add 1-2 drops of each of the three prepared solutions. The mixture will appear light yellow. Heat at 100-120 degrees C for 2-3 minutes and observe the color development.

* If the solution remains yellow and the resin becomes transparent, the coupling reaction is complete.
* If the solution or resin turns blue, free amino groups are present, indicating either incomplete coupling or successful deprotection.

Important Notes:

* Using too much resin may affect the results.
* Heating time must be controlled: too short may lead to false positives (incomplete color development), while too long may cause cleavage of the Fmoc group from the amino acid or the Boc group from lysine side chains, leading to false negatives.

2.Chloranil Test

The chloranil (tetrachlorobenzoquinone) colorimetric reagent is a commonly used chromogenic agent primarily for the detection of secondary amines (such as the amino group in proline), and it can also be applied to primary amines. Additionally, de-Fmoc reagents are typically secondary amines (e.g., piperidine, morpholine, dimethylamine). Therefore, the chloranil test can be used to detect peptide resins to determine whether residual secondary amines remain after de-Fmoc treatment with a secondary amine and whether they have been thoroughly washed away.

2.1 Preparation of Test Solutions

* Solution A: Add 2 mL of acetaldehyde to 98 mL of anhydrous DMF.
* Solution B:Dissolve 2 g of chloranil in 98 mL of anhydrous DMF.

Precautions: Chloranil is irritating. Gloves and safety goggles must be worn during handling. Direct skin contact or inhalation of powder is strictly prohibited. Maintain an anhydrous environment during preparation, as moisture may interfere with the detection reaction and lead to inaccurate results.

2.2 Testing Procedure

Using a capillary tube, transfer a small amount of washed resin into a test tube. Add two drops each of Solution A and Solution B. Mix thoroughly and let stand at room temperature for 5 minutes. If the resin turns bluish-green, it indicates the presence of free amino groups. If it remains colorless or pale yellow, the coupling reaction is complete.

3. Bromophenol Blue Test

The bromophenol blue test offers advantages such as simple operation, short processing time, rapid and sensitive color development, and low toxicity. The principle of this method is based on the fact that free amino groups (-NH) are basic and can undergo an acid-base reaction with bromophenol blue (an acidic indicator, pKa almost equal to 4.0). This reaction neutralizes H in the bromophenol blue solution, causing the indicator to change from "yellow (dissociated form, HIn)" to "blue (dissociated form, In)." It can be used to detect whether the coupling reaction in solid-phase peptide synthesis is complete. If the amino groups on the resin are not free (i.e., non-basic), the bromophenol blue solution will remain yellow. If free amino groups are present, their basicity will cause the bromophenol blue solution to change from yellow to blue.

3.1 Preparation of Test Solution

Weigh 1 g of bromophenol blue powder and dissolve it in a small amount of anhydrous DMF. Then add anhydrous DMF to a total volume of 100 mL and mix well. Transfer the solution to a brown bottle, label it, and store it sealed at 4 degrees C. For use, directly take the solution and add drops to test the resin.

3.2 Testing Procedure

Using a capillary tube, transfer a small amount of washed resin into a test tube. Add an appropriate amount of bromophenol blue reagent. If the solution immediately changes from yellow to blue, it indicates the presence of exposed amino groups on the resin, suggesting either complete deprotection or incomplete coupling.

Media Contact
Company Name: Beijing Dilun Biotechnology Co., Ltd.
Email:Send Email [https://www.abnewswire.com/email_contact_us.php?pr=commonly-used-colorimetric-reagents-in-spps]
Country: China
Website: https://www.peptidescientific.com/

Legal Disclaimer: Information contained on this page is provided by an independent third-party content provider. ABNewswire makes no warranties or responsibility or liability for the accuracy, content, images, videos, licenses, completeness, legality, or reliability of the information contained in this article. If you are affiliated with this article or have any complaints or copyright issues related to this article and would like it to be removed, please contact retract@swscontact.com



This release was published on openPR.

Permanent link to this press release:

Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.

You can edit or delete your press release Commonly Used Colorimetric Reagents in SPPS here

News-ID: 4204499 • Views:

More Releases from ABNewswire

PERGOLUX Expands U.S. Operations with New Southern California Showroom
PERGOLUX Expands U.S. Operations with New Southern California Showroom
Outdoor Living Brand Utilizes Montclair as Key Logistics Hub for Warehouse Expansion Montclair, CA - October 21, 2025 - PERGOLUX [https://pergoluxshop.com/pages/pergolux-events], the award-winning outdoor living brand known for its Scandinavian-designed smart pergolas, is expanding its U.S. operations with the launch of a new showroom and light manufacturing facility in Los Angeles. Opening to the public on October 25 from 11:00 AM to 8:00 PM PST, and continuing on October 26 from
Hanley Investment Group Brokers Sale of New 52,300-SF Amazon Facility at The Foundry, a 200-Acre Mixed-Use, Master-Planned Community in Bozeman Metro, Montana
Hanley Investment Group Brokers Sale of New 52,300-SF Amazon Facility at The Fou …
BELGRADE, Mont. - Hanley Investment Group Real Estate Advisors, a national real estate brokerage and advisory firm specializing in retail property sales, announced today the sale of a newly constructed Amazon-occupied, single-tenant property located within The Foundry, a 200-acre mixed-use master-planned development in Belgrade, Montana. The sales price was not disclosed. Hanley Investment Group's Eric Wohl and CJ Kiehler, in association with Venture West Development, LLC of Bozeman, Montana, represented the
Holiday Gift Guide From ZEELOOL: Eyewear from Prabal Gurung for Every Powerful Woman
Holiday Gift Guide From ZEELOOL: Eyewear from Prabal Gurung for Every Powerful W …
Holiday is the key moment to celebrate important families and friends. This year, it's time to celebrate those powerful women in your life. From the colleagues who inspired you to the families who supported you. Why don't present a gift which can reflect their strength and power. Holiday is the key moment to celebrate important families and friends. This year, it's time to celebrate those powerful women in your life. From
Micropolis Proves the Future of Robotics Isn't Coming, It's Already on Patrol (NYSE: MCRP)
Micropolis Proves the Future of Robotics Isn't Coming, It's Already on Patrol (N …
Micropolis is what happens when robotics stops being science fiction and starts shaping the real world. You can feel it in the streets of Dubai, where the company's machines move like extensions of the city itself. They don't just patrol, they perceive. They don't just respond, they anticipate. It's the kind of intelligence that rewrites what a smart city actually is, because Micropolis Holding Company (NYSE: MCRP [https://storage.googleapis.com/vendorgroup-assets/site/e4a718b2-1632-4aeb-ba1b-07c6669476e5/2025/09/16/68c9b1c1a93a5435b9bcc15d/Micropolis Holding IR PPT

All 5 Releases


More Releases for Test

Vitamin Test Market: Global Vitamin Test Analysis and Forecast (2023-2029)Vitami …
12.04.2024: Vitamin Test Market Overview The development of companion diagnostic tools and advances in personalised treatment are driving considerable growth and revolution in the oncology Vitamin Test market. In the era of precision medicine, where healthcare is increasingly customised for individual individuals based on their own genetic and molecular profiles, this market segment is essential. Ongoing innovation and development define the oncology Vitamin Test market. To find particular biomarkers, genetic mutations,
CAGR 8.1% Homecare Pregnancy Test Kits Market By Type of Test (Urine Test For H …
The Homecare Pregnancy Test Kits market report by Reports and Data provides an extensive overview of the vital elements of the Homecare Pregnancy Test Kits market and factors such as the drivers, restraints, latest trends, supervisory scenario, competitive landscape, technological advancements, and others. Further, it mentions the market shares associated with the market in terms of both value and volume along with the segmentation. Space-age industrial and digitalization tools are
Home Safety Test Kits Market, Home Safety Test Kits Market Trends, Home Safety T …
“Home Safety Test Kits Market” 2020-2025 Research Report is a professional and in-depth study on the current state of the market. Global Home Safety Test Kits market containing a complete view of the market size, business share, profit estimates, SWOT analysis and the regional landscape of the Industry. The report explains key challenges and future development prospects of the market. The Global Home Safety Test Kits analysis is provided for
Test Data Management (TDM) Market - test data profiling, test data planning, tes …
The report categorizes the global Test Data Management (TDM) market by top players/brands, region, type, end user, market status, competition landscape, market share, growth rate, future trends, market drivers, opportunities and challenges, sales channels and distributors. This report studies the global market size of Test Data Management (TDM) in key regions like North America, Europe, Asia Pacific, Central & South America and Middle East & Africa, focuses on the consumption
Hearing Screening and Diagnostic Devices Market Demands with Major Tests: pure T …
New Market Research Reports Title "Hearing Screening And Diagnostic Devices Market 2018" Has Been Added to Crystal Market Research Report database. Hearing Screening and Diagnostic Devices - Competitive Insights: The leading players in the market are Gn Otometrics A/S, Otodynamics, Nashua Hearing Group, Siemens Healthineers, Natus Medical Incorporated, Interacoustics A/S, Neurosoft S.A, Accent Hearing Pty Ltd, MAICO Diagnostics GmbH and IntriCon Corporation. The major players in the market are profiled in detail
Global Low Temperature Test Equipment Market Outlook 2017 : Ektron Tek, IEC Test …
Global Low Temperature Test Equipment Market 2017-2022 A market study ” Global Low Temperature Test Equipment Market ” examines the performance of the Low Temperature Test Equipment market 2017. It encloses an in-depth Research of the Low Temperature Test Equipment market state and the competitive landscape globally. This report analyzes the potential of Low Temperature Test Equipment market in the present and the future prospects from various angles in detail. The Global