openPR Logo
Press release

Application of DC Power Supply in Testing Superconducting Materials

09-05-2023 02:44 PM CET | Business, Economy, Finances, Banking & Insurance

Press release from: ITECH ELECTRONIC CO.,LTD.

Application of DC Power Supply in Testing Superconducting

Superconductors are conductors that have zero resistance and complete flux repulsion effects at a certain temperature. This characteristic sets them apart from all other conductive materials in that they do not lose energy or heat when current flows through them. If superconductors are used to make transformers, generators, motors, current limiters, and energy storage systems, efficient power grids and motors can be realized. Superconducting magnets made from superconducting coils can be used in magnetic resonance imaging and artificially controlled nuclear fusion and other fields. The antimagnetic properties of superconductors also make them an option for magnetic levitation trains.

The three main performance indicators of superconducting materials are the critical transition temperature (that is, the highest temperature for becoming a superconducting state), the critical magnetic field (that is, the minimum magnetic field that can destroy the superconducting state), and the critical current (the maximum current for the material to maintain a superconducting state).

Four lead method test wiring diagram
Experiments found that when a current flows through a superconductor, the superconductor remains unimpeded and has an upper limit to the current, which is called the critical current of the superconductor. When the current passing through is greater than the critical current, the superconductor appears resistance. The higher the critical current of a superconductor means that the superconductor can withstand a larger current and is more superconductive. A basic method for measuring the critical current of a superconductor is the four-lead method, which applies a DC constant current power supply to the superconductor, and the current when the voltage appears is the critical current value. ITECH IT-M3900 series dc power supplies have the characteristics of high speed and high precision, and the built-in CC/CV priority function can better control the constant current output, which can meet the requirements of superconducting testing.

IT-M3900 series power supply includes IT-M3900B regenerative power system, IT-M3900C bidirectional programmable DC power supply and IT-M3900D high-power programmable DC power supply. Among all the models, the 1U model can reach 510A, the 2U model can reach 1020A, and the maximum current for parallel machines can reach 8000A, which is suitable for testing the critical current of superconducting products as well as ATE testing and building.

No.918, Zhongzheng Rd., Zhonghe Dist., New Taipei City 23586, Taiwan

As a professional manufacturer of power electronics testing instruments and systems, ITECH always keeps the spirit of continuous innovation and excellent quality since established. The long term investment on research and development of new technology creates high performance products and reliable user experience.
Until now, ITECH has brought to the market over 700 products including AC/DC power supply, AC/DC electronic load, power meter, battery IR tester, power system, etc.

This release was published on openPR.

Permanent link to this press release:

Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.

You can edit or delete your press release Application of DC Power Supply in Testing Superconducting Materials here

News-ID: 3195699 • Views:

More Releases from ITECH ELECTRONIC CO.,LTD.

Powering the AI Era: How UPS and PDU Systems Evolve to Meet Demands of Modern AI …
With the explosive growth of generative AI, hyperscale data centers are facing an unprecedented surge in power density, thermal load, and system uptime requirements. Unlike traditional computing loads, AI training and inference workloads are characterized by massive GPU clusters running at near-peak utilization, demanding a stable, scalable, and intelligent power infrastructure. The Power Challenge in AI-Driven Data Centers AI training workloads often push rack densities beyond 30kW-and in some setups, even over
Designed for Distributed Photovoltaic Testing--ITECH IT-N2100 Solar Array Simulator
Designed for Distributed Photovoltaic Testing--ITECH IT-N2100 Solar Array Simula …
Photovoltaic power generation can be divided into centralized and distributed photovoltaic power generation. Since the second half of 2021, the policy of promoting distributed photovoltaic throughout the county has detonated the distributed photovoltaic market. ITECH has launched the IT-N2100 series of solar array simulators for the testing of distributed photovoltaic components, such as micro-inverters and power optimizers. IT-N2100 series solar array simulator is a high-performance DC power supply with fast

More Releases for Superconducting

Superconducting Magnet for Medical MRI System Market Size, Growth Analysis 2031 …
USA, New Jersey: According to Verified Market Reports analysis, the global Superconducting Magnet for Medical MRI System Market size is reached a valuation of USD 2.5 Billion in 2023, with projections to achieve USD 4.3 Billion by 2031, demonstrating a CAGR 7.0% from 2024 to 2031. What is the current state and growth potential of the Superconducting Magnet for Medical MRI System Market? The Superconducting Magnet for Medical MRI System Market is
What's Driving the Superconducting Magnetic Energy Storage Market 2025-2034: Ris …
What Are the Projections for the Size and Growth Rate of the Superconducting Magnetic Energy Storage Market? In the past few years, the market size of superconducting magnetic energy storage has witnessed significant growth. It is projected to expand from $55.4 billion in 2024 to $60.42 billion in 2025, with a compound annual growth rate (CAGR) of 9.1%. Factors contributing to the growth in the historical period include increasing energy
Transforming the Superconducting Materials Market in 2025: Superconducting Mater …
What Is the Expected Size and Growth Rate of the Superconducting Materials Market? The market size of superconducting materials has experienced a swift expansion recently. An increase from $8.94 billion in 2024 to an estimated $9.92 billion in 2025 is forecasted, signifying a compound annual growth rate (CAGR) of 11.0%. The impressive growth during the historical phase can be traced back to factors such as research and development efforts, government subsidies
Superconducting Magnet for Medical MRI System Market Size, Share and Forecast By …
𝐔𝐒𝐀, 𝐍𝐞𝐰 𝐉𝐞𝐫𝐬𝐞𝐲- According to the MRI Team's Market Research Intellect, the global Superconducting Magnet for Medical MRI System market is anticipated to grow at a compound annual growth rate (CAGR) of 13.01% between 2024 and 2031. The market is expected to grow to USD 27.57 Billion by 2024. The valuation is expected to reach USD 64.89 Billion by 2031. The Superconducting Magnet for Medical MRI System market is experiencing significant
Superconducting Materials Market Size & Share Analysis
The Business Research Company has recently revised its global market reports, now incorporating the most current data for 2024 along with projections extending up to 2033. Superconductors Global Market Report 2024 by The Business Research Company offers comprehensive market insights, empowering businesses with a competitive edge. It includes detailed estimates for numerous segments and sub-segments, providing valuable strategic guidance. The Market Size Is Expected To Reach $12.83 billion In 2028 At
Global Superconducting Wires Market Insights, Forecast
The Superconducting Wires market was valued at Million US$ in 2017 and is projected to reach Million US$ by 2025, at a CAGR of during the forecast period. In this study, 2017 has been considered as the base year and 2018 to 2025 as the forecast period to estimate the market size for Superconducting Wires. Get sample copy of the report: https://www.marketdensity.com/contact?ref=Sample&reportid=52616 Table of Contents: Table of Contents 1 Study Coverage 1.1