Identify and Help Prevent Risks in Hospital & Pharma Cleanrooms

Many hospital and pharmaceutical technicians know that they need to establish an environmental monitoring plan/regime for their cleanroom, but CDC regulations are many and varied. How do you tie together the many different requirements to monitor, alarm and document the data?

If you work in a cleanroom monitoring application such as a product fill cleanroom, in non-sterile manufacturing, or in a medical cleanroom, this latest White Paper from CAS DataLoggers can help you to get started on an actionable monitoring plan.
Environmental Monitoring Basics:

Whether you’re a Surgical Technician, Quality Engineer, or Pharmaceutical Microbiologist, passing your standards audit will require a comprehensive monitoring plan.

CDC LogoCDC (Centers for Disease Control and Prevention) guidelines on environmental measurement in cleanrooms and isolated areas state: “Do not conduct random, undirected, microbiologic sampling of air, water, and environmental surfaces in health-care facilities (270,343). Category IB.”

The main risk to cleanrooms is the loss or reduction of sterility assurance and the subsequent microbiological contamination that follows. Environments are monitored to protect pharmaceutical products from contaminants and to prevent OOS (out of specification), OOL (out of limit), and OOT (out of trend) alarm events from occurring. This is the equivalent of the modern healthcare industry placing its emphasis on prevention rather than cure.

Isolated areas require both air and surface monitoring to achieve sterilization/decontamination. Without recourse to historical data in the form of stored measurements, technicians lack any reliable way to determine sterilization effectiveness.

Carefully consider the requirements of your specific class of cleanroom as they relate to measurement collection. For example, when working in isolated environments graded Class A, C and D, personnel should routinely sample the air and swab the surfaces. If your class mandates the daily use of particle counters (Grade A esp.) then consider using an automated monitoring system with remote monitoring capability for instant access to alarms.

Note that settle plates, although often used as a simple way to roughly gauge the level of microbial contaminants, are not by themselves sufficient to ensure sterilization or to pass an audit. If you plan on using an environmental monitoring system, be sure to set it to monitor even throughout the duration of settle plate use. The CDC’s guidelines state: “Do not use settle plates to quantify the concentration of airborne fungal spores (348). Category II”

An especially high risk to cleanrooms is posed by gram-negative bacteria which contaminate water and produce most toxics found in the microclimate. It’s a common problem in aseptic processes, generating endotoxins which cause disease. Product fill cleanrooms in particular are a good breeding ground for these bacteria since there are often multiple exposed petri dishes located throughout the cleanroom for research purposes.

This and other risks can be addressed by developing your own incubation regime, which in many cases requires specialized equipment. For example the CDC recommends to: ”Use standard cleaning and disinfection protocols to control environmental contamination with antibiotic-resistant, gram-positive cocci (e.g., methicillin-resistant Staphylococcus aureus, vancomycin intermediate sensitive Staphylococcus aureus, or vancomycin-resistant Enterococcus [VRE]) (318,320–322). Category IB.”

Before you consider the further details of your monitoring plan, ask yourself, are you planning on taking measurements manually or automatically?

Manually: A major source of contamination in labs is caused by personnel taking frequent manual measurements. The more frequent these manual samples are, the higher chance of microbial contamination.
Automatically: Automated monitoring systems can provide your business or organization with the technology to cut labor costs, save time, and measure your critical values at high accuracy. Full regulatory compliance with patient privacy and electronic documentation standards is possible using all the advanced archival and documentation capabilities available with system software.


Monitor, Alarm and Validate

Regular environmental measurements, whether taken manually or performed by an automated monitoring system, form the foundation of your individual risk assessment strategy. When conducted at the appropriate times and frequencies, these measurements give personnel time to take remedial action before product quality and/or environmental sterility are threatened.

For instant notification, many environmental monitoring systems feature wireless communication, giving users the ability to remotely receive alarms and monitor data in real-time. This capability is especially useful for maintaining Grade A cleanrooms and other areas with gram-negative bacteria.

Accurate data measurement is also useful for out of limit (OOL) and out of specification (OOS) investigations, which determine why a given alarm went off. Finally, monitoring systems save all data for documentation and audit/validation purposes.

Your environmental monitoring plan should contain these three key factors:

Determine Your Monitoring Points:

Your facility’s monitoring point layout depends on the size and area of your isolated environment. First determine where you need to take readings or to install sensors in your given cleanroom, hospital corridor, surgery, or other area. Your layout also depends on the level of risk to patient health or to product quality, for example whether you have an open or a closed process. As a good guideline, you’re safer having more monitoring points rather than less.

Before placing sensors, it’s critical to determine the area’s risk level using a designation of Low, Mid or High. In high-risk cases such as gram-negative bacteria applications, your installed sensors need a high accuracy to address the main risk of losing sterility through microbiological contamination.

Prioritize these areas:

Areas with higher travel/population (corridors, surgery prep areas, etc.)
Areas with longer work or incubation durations
Dirty or wet areas
Any significant variations within rooms

Putting this type of forethought into sensor placement helps you to determine how best to detect specific fungi/bacteria in operation-dependent regimes. This includes not only surface measurements but also active air sampling (volumetric air-samplers, particle counters etc.).

To accommodate a wider sensor grid, cleanroom monitoring systems are available in configurations with anywhere from one to hundreds of inputs. This makes them ideal to monitor filling machine cleanrooms, ISO 5 product fill cleanrooms, test sample incubation, non-sterile manufacturing, and many other applications.

Choose Monitoring Frequencies:

Also known as sampling rate, your monitoring frequencies should generally be performed frequently, at minimum recording a reading at each batch filling, at defined intervals, or immediately after sanitizing isolated & sterile areas.

You should also take a reading following:

Essential maintenance
Monthly/quarterly monitoring
Incubation of test samples
Critical times and temperature windows of operation-dependent regimes.

Monitoring systems can also accommodate different sampling rates for different cleanroom types. Your particular monitoring frequency will often depend on your individual cleanroom’s class, rated by the ISO (International Organization for Standardization). Example classes include:

ISO 5: Common examples are applications with specified filling points in liquid containers. Monitoring frequency needs to be either daily or at the end of each batch, whichever is higher.
ISO 7: This class includes gowning rooms and other applications which have surrounding areas rated at ISO5; here a weekly monitoring frequency is indicated.

Monitoring Systems and Sampling Rate:

As we covered in an earlier article, ‘How Fast Should You Sample on Your Thermocouples?,’sampling rate is highly dependent upon your individual application needs.

Modern environmental monitoring systems can sample data once every second or faster, which is more than enough for most cleanroom applications. Note that a high sample rate is inversely tied to system battery life and the specifications of the specific device chosen. Recording duration can be determined by dividing the data logger’s memory capacity by its sample rate. However, many monitoring systems utilize a non-volatile memory to ensure that all recorded data is still safe if the battery fails or power is lost.

In most cleanroom applications, your temperatures won’t fluctuate several times a second. With this in mind, you can configure your data loggers at a lower sampling rate (say, once every five or ten minutes depending on the measurement value). This helps to save device memory space and time spent trending data during analysis.

Applications that may require faster sampling rates include advanced scientific research, high-speed equipment tests, etc. If you do need to sample at extreme rates of several readings a second, you’ll need to use small sensors, and the material you’re monitoring has to have a small thermal mass, unlike when monitoring typical industrial process temperatures.

Documentation and Validation:

Full data documentation and subsequent validation is the third major component of an effective cleanroom monitoring regimen. For audit and standardization purposes, all your data and methodology needs to be recorded and validated, both for your own use and for inspectors. As part of this process, be sure to itemize your monitoring plan to give to auditors later.

Trending Environmental Data:

Armed with several months or a year’s worth of collected environmental data, you can, in many applications, examine it all in trend format to determine your plan’s effectiveness. Whether your regime is working as intended and you can consequently reduce sampling rate, or whether you find that your plan needs to be reconsidered, validation is a key reason to trend your data. Also be sure that your assembled data is easily accessible to inspectors on short notice.

Any and all cleanroom validation solutions need to be able to automatically record, store, and trend your environmental data. By using data logger software, you can view historic data by specific filters. This is an easy way to view all alarm violations over a given period, which helps in OOS/OOL investigations to discover why alarms triggered in the first place.

As part of good manufacturing practice (GMP), be on the lookout for microflora and specifically for resistant bacterial strains. Unlike settle plates, trended data can give you a detailed view of microbial contamination levels, leading to final validation.
Summary:

Effective sterility assurance in cleanrooms and other isolated areas requires users to Monitor, Alarm and Validate as the three critical tenets of a comprehensive environmental monitoring plan. These mutually-complementary concerns give you actionable items to consider as you determine the ideal regime for your facility’s needs. With forethought and using a combination of sensors and software, you can help to ensure your facility’s environmental integrity and thereby achieve validation.
About the Authors:

CAS DataLoggers environmental monitoring systems are installed in a variety of hospital cleanrooms, pharmaceutical cleanrooms, government health centers, manufacturing plants, museums and galleries, and in all manner of additional applications.



To learn more about Cleanroom Monitoring Solutions, or to find the ideal solution for your application-specific needs, contact a CAS DataLoggers Application Specialist at (800) 956-4437.

Computer Aided Solutions, LLC. dba CAS DataLoggers is a distributor of data loggers, paperless recorders and data acquisition equipment.

CAS Dataloggers
8437 Mayfield Rd
Chesterland, OH 44026
www.dataloggerinc.com

This release was published on openPR.

Permanent link to this press release:

Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.

You can edit or delete your press release How to Establish a Cleanroom Monitoring Plan here

News-ID: 730356 • Views:

More Releases from CAS DataLoggers

New AirGate 4G Cellular Router from Novus
New AirGate 4G Cellular Router from Novus
NOVUS presents AirGate 4G, an industrial VPN router for cellular networks. Data sending is secure with this new device as it uses encryption protocols and firewall systems most commonly used in IT infrastructures, including automatic fallback for 4G, 3G, and 2G cellular networks. AirGate 4G is CE Mark certified and was developed for industrial environments. It can maintain its high availability performance even in extended operation situations, being equipment suitable
New AERINOS ADS-300 from Infinite Informatics
New AERINOS ADS-300 from Infinite Informatics
New Wireless NB-IoT/LTE-M Data Collection End Node CAS DataLoggers is pleased to introduce the new AERINOS ADS-300 wireless sensor end node from Infinite Informatics. The ADS-300 is designed to transmit data via either NB-IoT/LTE-M cellular networks and is targeted at remote monitoring applications. NB-IoT is a wireless protocol designed for the Internet of Things that offers very low-power operation using either existing GSM or newer LTE cellular technology. NB-IoT is a
New TR32B Bluetooth Data Logger From TandD
New TR32B Bluetooth Data Logger From TandD
CAS DataLoggers is pleased to announce the updated TR32B log-EZ as an effective low-cost solution for temperature and humidity measurement. The log-EZ is designed as a compact, user-friendly data logger to easily measure and record ambient temperature and humidity. It provides Bluetooth communication and a smartphone/tablet app that can display and upload data to the cloud. The TR32B provides a measurement range of 0° to 50° Celsius (32° to 122°
New A2-06 Temperature & Alarming Monitoring Pod by CAS
New A2-06 Temperature & Alarming Monitoring Pod by CAS
Medical storage applications depend heavily on monitoring the temperature of their goods in cold storage to protect items such as vaccines, blood, medicine, and tissue samples. CAS DataLoggers is pleased to introduce the A2-06 Ethernet Wired Temperature Measurement Pod designed for measuring temperatures in medical refrigerators, freezers, incubators, and in cryogenic storage. The pod is an Ethernet LAN-wired temperature monitor with connections for two external RTDs and a thermocouple sensor.

All 4 Releases


More Releases for Monitor

Patient Home Monitoring Market 2020: Emerging Medical Technologies and Top Compa …
This report is subjective and qualitative Research of the Global Patient Home Monitoring Market 2020 industry is complete analysis which helps later on assessment of the market. The comprehensive Report will help clients to comprehend the market ups-down, different drivers, share, investigation, size, application, supply, and numerous different angles. This Report is segmented on basis of type, application, end users and geographical regions. Get sample copy of this report at
Gas Exchange Monitor Market to Record an Exponential CAGR by 2028(Gas Exchange M …
Gas Exchange Monitor: Market Insights Gas exchange monitor is used to monitor and measure a variety of respiratory-related disorders and provide information regarding the patient’s lung conditions. Gas exchange monitor device measures the volume flow of two main gases such as oxygen and carbon dioxide per unit time. The increasing prevalence of respiratory disorder and rising demand for better treatment options by the population boosting the gas exchange monitor market. According
Global Industrial Flame Monitor Market 2018 - Maxon, Sierra Monitor, Emerson, Fi …
Accord Market, recently published a detailed market research study focused on the “Industrial Flame Monitor Market” across the global, regional and country level. The report provides 360° analysis of “Industrial Flame Monitor Market” from view of manufacturers, regions, product types and end industries. The research report analyses and provides the historical data along with current performance of the global PP Pipe industry, and estimates the future trend of Industrial Flame
Smart Baby Monitor Market Report 2018: Segmentation by Product (Audio Baby Monit …
Global Smart Baby Monitor market research report provides company profile for Graco, Levana, Angelcare, WiFi Baby, Lorex, Philips, Withings, Safety 1st, Motorola, Summer Infant, Samsung, Infant Optics and Others. This market study includes data about consumer perspective, comprehensive analysis, statistics, market share, company performances (Stocks), historical analysis 2012 to 2017, market forecast 2018 to 2025 in terms of volume, revenue, YOY growth rate, and CAGR for the year 2018 to
Monitor Data Integrity with Active@ Hard Disk Monitor
LSoft Technologies, one of the world's leading suppliers of disk and data utilities, presents Active@ Hard Disk Monitor: a complete solution for monitoring the health of your digital storage devices. This software provides full monitoring and control over your data by providing ongoing insights into its integrity and the status of your storage devices. In other words, if a drive looks like it might be about to fail, you'll know
ECG Monitor market
This report presents a 360-degree overview of the competitive scenario of the Global ECG Monitor market. Thus helping organizations understand the major threat and opportunities that vendors in the market are dealt with. It also includes detailed business profiles of some of the major vendors in the market. With the all-inclusive market data concerning the crucial elements and segment of the market that can influence the growth prospects of the