openPR Logo
Press release

Synchronized Acquisition of Power Data

09-27-2017 03:44 PM CET | Industry, Real Estate & Construction

Press release from: CAS DataLoggers

Delphin LogMessage Data Acquisition Systems

Delphin LogMessage Data Acquisition Systems

Product Testing Applications Made Simpler
Product testing requires not only the conventional data acquisition of analog signals such as temperatures, pressures and flows, but also often the simultaneous acquisition of power data. This power data normally needs to be acquired in the form of AC values from the primary-side supply. Other relevant values include actual, apparent and idle power as well as cos phi, crest factor and TRMS for currents and voltages. For frequency converters, technicians also require a secondary-side measurement, ranging from DC values to high-frequency and distorted AC values.
Delphin Message devices are convenient solutions for these multi-value data acquisition applications. Single or 3-phase power measurement units can be connected to Delphin Message devices via a serial interface. This provides users with an optimal setup to synchronously acquire, monitor and evaluate all data in a single system.
Application features:
• Synchronous acquisition of power data and conventional process data in a single system
• Data acquisition of characteristic values for power measurement (TRMS, vertex, crest, peak values, etc.)
• Optional connection of power measuring units from different manufacturers
• Online computation of power data with other measurement data
• Measurements for energy efficiency according to the EN 50001 standard
Example: Electrical power and temperature measurement at a pump test stand:
A German pump manufacturer supplies its products with integrated frequency converters. Final product testing after production includes 100% testing of each pump at an automated end-of-line test stand. Technicians take measurements for temperatures, pressures, vibrations, and power input.
All their measurement data is acquired using a single Delphin data logger. The power data is acquired as 3-phased via an integrated power measurement unit using current clamps and voltage converters. Meanwhile connection to the Delphin Message device takes place via Modbus.
All relevant power data is acquired and recorded using an application generated by Delphin ProfiSignal software. This customer is using the ProfiSignal Klicks version designed for automation, and stores data according to serial numbers via reports. The system is connected to a PPS (Paint Preparation System) via an SQL interface.
Typical areas of application:
• Measurement of electrical power in pumps and drives
• Combined power measurement at motor test stands
• Electrical power measurement of household appliance testing stands
• Analysis of power parameters
• Acquisition of the energy footprint for frequency converters
• Measurement for refrigeration and cooling systems
Need Help? Call the Application Experts!
At CAS DataLoggers we offer hundreds of application-specific data loggers and universal DAQ systems. Whether you’re just getting started or you know exactly what you’re looking for, all the options when choosing a data logger or data acquisition system can be overwhelming. We can help.
To learn more about Delphin systems, or to find the ideal solution for your application-specific needs, contact a CAS Data Logger Applications Specialist at (800) 956-4437 or visit our website at www.DataLoggerInc.com.

Computer Aided Solutions, LLC. dba CAS DataLoggers is a distributor of data loggers, paperless recorders and data acquisition equipment.

CAS DataLoggers
8437 Mayfield Rd
Chesterland OH 44026
sales@dataloggerinc.com

This release was published on openPR.

Permanent link to this press release:

Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.

You can edit or delete your press release Synchronized Acquisition of Power Data here

News-ID: 744044 • Views:

More Releases from CAS DataLoggers

New AirGate 4G Cellular Router from Novus
New AirGate 4G Cellular Router from Novus
NOVUS presents AirGate 4G, an industrial VPN router for cellular networks. Data sending is secure with this new device as it uses encryption protocols and firewall systems most commonly used in IT infrastructures, including automatic fallback for 4G, 3G, and 2G cellular networks. AirGate 4G is CE Mark certified and was developed for industrial environments. It can maintain its high availability performance even in extended operation situations, being equipment suitable
New AERINOS ADS-300 from Infinite Informatics
New AERINOS ADS-300 from Infinite Informatics
New Wireless NB-IoT/LTE-M Data Collection End Node CAS DataLoggers is pleased to introduce the new AERINOS ADS-300 wireless sensor end node from Infinite Informatics. The ADS-300 is designed to transmit data via either NB-IoT/LTE-M cellular networks and is targeted at remote monitoring applications. NB-IoT is a wireless protocol designed for the Internet of Things that offers very low-power operation using either existing GSM or newer LTE cellular technology. NB-IoT is a
New TR32B Bluetooth Data Logger From TandD
New TR32B Bluetooth Data Logger From TandD
CAS DataLoggers is pleased to announce the updated TR32B log-EZ as an effective low-cost solution for temperature and humidity measurement. The log-EZ is designed as a compact, user-friendly data logger to easily measure and record ambient temperature and humidity. It provides Bluetooth communication and a smartphone/tablet app that can display and upload data to the cloud. The TR32B provides a measurement range of 0° to 50° Celsius (32° to 122°
New A2-06 Temperature & Alarming Monitoring Pod by CAS
New A2-06 Temperature & Alarming Monitoring Pod by CAS
Medical storage applications depend heavily on monitoring the temperature of their goods in cold storage to protect items such as vaccines, blood, medicine, and tissue samples. CAS DataLoggers is pleased to introduce the A2-06 Ethernet Wired Temperature Measurement Pod designed for measuring temperatures in medical refrigerators, freezers, incubators, and in cryogenic storage. The pod is an Ethernet LAN-wired temperature monitor with connections for two external RTDs and a thermocouple sensor.

All 4 Releases


More Releases for Delphin

New ProfiSignal 20 Software Package From Delphin
CAS is pleased to announce the new ProfiSignal 20 (PS20) software package from Delphin Technology. This software provides platform independence by allowing data collected with Delphin data acquisition systems to be visualized and analyzed on a PC, tablet, or smartphone. ProfiSignal 20 is available in several versions depending on the application requirements. The “Go” version can be used for quick visualization, monitoring, and archiving of measurement data. It includes configurable single
Delphin Releases New ProfiSignal Web Software
Web-Based Software for Measurement & Testing CAS Dataloggers is pleased to announce the release on the new ProfiSignal Web Software package from Delphin Technology. ProfiSignal Web is state-of-the-art application for measurement and monitoring that allows decentralized data acquisition, centralized data storage and browser-based monitoring using a PC or mobile device. Accessing and analyzing measurement data from Industrial, Environmental or Life Science applications has become more flexible than ever before. Whether for
Delphin Offers Extensive Driver Development
Let Delphin Develop Your Application! For flexible use in many different measurement applications, communication between Delphin data loggers and third-party ICA technology is possible using standard protocols. The communication interfaces in Delphin ProfiSignal software and hardware provide a multitude of options for exchanging data. CAS DataLoggers distributes Delphin dataloggers in the US--just contact us at 1-800-956-4437 if you have questions about connecting an ICA system to Delphin hardware or software.
Delphin Upgrades ProfiSignal Measurement Software
Version 4.2.10 Available for Download at CAS DataLoggers CAS DataLoggers and Delphin Technology are proud to announce the release of an improved version of Delphin’s popular ProfiSignal data acquisition software. Version 4.2.10 adds new bug fixes as suggested by users around the world. You can download the new version from our Delphin Downloads page at http://www.dataloggerinc.com/downloads/delphin.php. Whether you work in test, process control or another application, at CAS DataLoggers we can
Precision Electrical Measurement Using Delphin
Fully-Automated Engine Test Stands Motor Test stands are required during the automotive R&D phase for serial testing and also for endurance trials. Measurements taken during the developmental phase such as Temperature and Voltage are fully-automated whenever possible. Sensors check the electrical and mechanical properties of the test sample as well as temperature patterns and overload operation. Testing conditions can vary widely--from the tiniest of motors to large drives in the megawatt
Delphin Systems Provide SDI-12 Sensor Integration
Versatile Data Logger Connects to Enviro Smart Sensors The SDI-12 interface (Serial Data Interface at 1200 Baud) enables, via a digital signal, the establishment of a connection with multiple "low-power" sensors and a data logger. Sensors can be operated on the bus with asynchronous, serial communication protocols. Such sensors (e.g. for soil moisture, soil temperature, air humidity, water potential, electrical conductivity, etc.) are primarily used in environmental engineering. Now users can