Testing of CANopen devices via USB and Ethernet
CANopen is a standardized communication protocol for embedded applications based on the CAN field bus. Manufacturer of CANopen devices check the compliance of their hardware implementations to these CANopen standards by conformity checks. This can be done by using an official test tool, the CANopen Conformance Test Tool.CAN in Automation (CiA) provides a CANopen Conformance Test Tool (CTT), which checks the device conformity to the CANopen specification CiA DS301. The tool may be used by members and non-members of the user group. The CiA itself uses the tool to make interoperability tests and for certification of CANopen devices.
The tool in actual version 3.0 is running on a windows pc und needs a CAN hardware adapter and a COTI.dll (CANopen Testing Interface). The COTI library for AnaGate CAN adapters are included in the scope of delivery of the CTT. The newest version of the library can additionally downloaded from the support pages of Analytica for free.
All AnaGate CAN bus adapters of Analytica can be used together with the CTT of the CiA. Here should be emphasized that the interconnection to the CANopen device can be done over ethernet by using one of the AnaGate models providing an ethernet interface
Individual hardware and software development in technical fields of application
The company Analytica GmbH based in Karlsruhe is an innovative and independent system house. Since it was established in 1996, the main lines of its activity are IT-consulting, supply of complete solutions in the field of communication, motion control and complex automation.
Focus is been put on development and assembly of microprocessor-controlled electronic hardware and associated software solutions.
ANALYTICA GmbH
Vorholzstrasse 36
76137 Karlsruhe
phone +49-721-35043-0
fax +49-721-35043-20
This release was published on openPR.
Permanent link to this press release:
Copy
Please set a link in the press area of your homepage to this press release on openPR. openPR disclaims liability for any content contained in this release.
You can edit or delete your press release Testing of CANopen devices via USB and Ethernet here
News-ID: 311268 • Views: …
More Releases from Analytica GmbH
CAN adapter providing up to 8 CAN interfaces
Accessing CAN bus with embedded computer
CAN (Controller Area Network) is an asynchronous serial bus system which was developed by Bosch in 1983 for networking control units in motor vehicles. CAN field busses are used in numerous areas today: in automation, the automotive industry and medical technology, in aircrafts and trains as well as in marine, aerospace, industrial and engineering industries. Access to the CAN bus was made by standard…
Providing SocketCAN supoort
The Anagate CAN adapters by Analytica (Germany) now provide support for SocketCAN. This means, users have access to the CAN network under the Linux operating system.
SOCKETCAN is an official part of the Linux kernel and therefore the standard interface to CAN hardware under Linux operating systems. It was contributed by Volkswagen as open source to the kernel – formerly known as Low Level CAN Framework (LLCF).
Analytica has offered professional products…
CAN-USB-Gateway operates also stand-alone
Robust and flexible at an economical price
Specialized in the range of networked personal and embedded computer systems, Analytica GmbH, Karlsruhe, offers different CAN-Ethernet-Gateways that have already proven themselves in a large number of applications. This product line was now extended: the AnaGate CAN USB (picture 1) can interconnect a personal computer with a CAN bus network via USB. Unlike other manufacturers, Analytica encloses the CAN telegrams in TCP/IP telegrams and…
Smart access to CAN field bus with LUA scripting language
Karlsruhe, 18. October 2010.
Analytica GmbH manufactures and markets CAN-Ethernet-Gateways which feature individual access to CAN field bus by the standard network interface of a personal computer. Access to the CAN bus is usually done by an existing programming interface (API) which can be used in self-created application programs.
In addition to this traditional programming method, users of the AnaGate products can now quickly create program batch files in LUA…
More Releases for CANopen
emtas CANopen FD support for STMicroelectronics STM32H7
Merseburg, March 2017 - At the Embedded World emtas GmbH presents its new CANopen FD protocol stack running on STMicroelectronics STM32H7 micro controller with CAN FD support.
Based on its field proven CANopen protocol stack emtas has developed their new CANopen FD protocol stack. Having used PC-based CAN FD interfaces hitherto, the CANopen FD stack has now been ported to the STM32H7 micro controller – one of the first industrial micro…
CANopen Protocol stacks for Fujitsu MB9BF506n
Merseburg, 04/25/2013 – emtas GmbH located in the heart of Germany has extended its Master and Slave CANopen stacks to support the Fujitsu Semiconductor MB9BF506n microcontroller from the FM3 family. This efficient controller is based on the ARM Cortex-M3 with a clock rate up to 80MHz using 2 integrated CAN-controller of the widely used C_CAN from Bosch. This combination of devices is an ideal base for CANopen applications using…
CANopen protocol stack with application designer
emtas GmbH announces the release of version 1.0 of their CANopen Slave and Master stacks. The CANopen Slave Basic version is meant for the development of small CANopen Slaves with basic functionality. The Master/Slave version can be used to develop sophisticated CANopen slave or master applications. The stacks are written completely in ANSI-C and comply with most of the MISRA-C rules. The hardware-specific interfaces are separated in driver packages…
PROFINET-CANopen gateway
Powerful gateway enabling easy integration of CANopen devices in PROFINET networks
With its new PROFINET-CANopen gateway "COP-CON 220/PN", IXXAT offers a powerful and easily configurable gateway solution for connecting CANopen devices and networks to PROFINET systems.
The gateway enables bi-directional data exchange allowing for both the integration of existing, low-cost CANopen devices into PROFINET systems as well as the provision of data from PROFINET for use in CANopen. At this, the gateway…
New CANopen Master API Version 6
With the CANopen Master API, IXXAT offers a proven solution for a quick and easy development of PC based CANopen® control, test and service applications under Microsoft Windows.
IXXAT Automation is pleased to announce the updated and expanded CANopen Master API V6. Along with the active CAN interfaces, CANopen Master API V6 supports IXXAT’s low-priced passive interfaces.
The new API can operate up to 12 CAN interfaces in parallel, and, depending…
New CANopen extension for IXXAT's canAnalyser
With the new version 2.7 of the CANopen module, IXXAT offers a revised and considerably extended version of its proven CANopen extension for the canAnalyser.
The CANopen module is an extension for the canAnalyser 2.7, enabling the display of received layer-2 messages according to the CANopen notation. At this, received messages are analyzed according to the communication objects defined in the CANopen protocol and assigned to the nodes. The message content…